Enclosed Panelboard FW972181 in 1997 LD 30IB July 07, 2020, 04:00:52 pm 30amp fuse came loose and burned up enclosed panelboard FW972181,,Any ideas where to find a replacement? I've spent hours looking for the panelboard.
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #1 – July 07, 2020, 06:18:53 pm Quote from: JimM - July 07, 2020, 04:00:52 pm30amp fuse came loose and burned up enclosed panelboard FW972181,,Any ideas where to find a replacement? I've spent hours looking for the panelboard.Year and model of Lazy Daze?Chris
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #2 – July 07, 2020, 06:26:27 pm Does it look like this?7300 Series 12V Fuse Board 036-7100-002 - RV Parts Express - Specialty RV...Larry 1 Likes
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #3 – July 07, 2020, 07:15:20 pm The Lazy Daze is a 31IB 1997.
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #4 – July 07, 2020, 07:18:36 pm The enclosed panelboard holds the 30amp breaker and two more breakers. Thepanel melted and will not support the 30amp breaker. The submitted picture isn't what I'm asking about.
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #5 – July 07, 2020, 07:45:19 pm Quote from: JimM - July 07, 2020, 07:15:20 pmThe Lazy Daze is a 31IB 1997.Thanks, Jim, and welcome to the Lazy Daze Owners' Group.Chris 1 Likes
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #6 – July 07, 2020, 11:26:45 pm "The Lazy Daze is a 31IB 1997."Thirty foot I can believe... the 31' models didn't come out until much later! 1 Likes
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #7 – July 07, 2020, 11:29:42 pm The enclosed panelboard is what can be seen in this photo.Know the Parts of an RV Distribution Panelthis site shows what I am asking about. the large breakers are fastened to the panelboard. It is a separate component.
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #8 – July 07, 2020, 11:34:57 pm Thanks for the correction...It is a 30IB 1997
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #9 – July 08, 2020, 12:23:19 am If I am understanding this, you burned up the module in the AC distribution section that has the AC bus bar that the breakers snap into. The word "fuse" in the OP was a bit misleading. You likely have a Parallax/Magnatek 6345 or 7345 power distribution center. Poking around a bit online I could not find anyone selling this part. You may have to replace the entire power distribution center. This would be the ideal time to replace the converter power supply with a much better "smart charger". One of the best things I did when we had an LD was upgrade the converter with a Progressive Dynamics 9270.Art 3 Likes
Re: Enclosed Panelboard FW972181 in 1997 LD 30IB Reply #10 – July 08, 2020, 07:21:35 am Quote from: Older_Fossil - July 08, 2020, 12:23:19 amIf I am understanding this, you burned up the module in the AC distribution section that has the AC bus bar that the breakers snap into. The word "fuse" in the OP was a bit misleading. You likely have a Parallax/Magnatek 6345 or 7345 power distribution center. Poking around a bit online I could not find anyone selling this part. You may have to replace the entire power distribution center. This would be the ideal time to replace the converter power supply with a much better "smart charger". One of the best things I did when we had an LD was upgrade the converter with a Progressive Dynamics 9270.ArtThanks Art! I agree with your idea. The 1997 LD 30IB now belongs to my cousin who lives just down the road from me. I now own a 2001 LD 30IB. The original converter was way too loud for me as I am a light sleep so I did replace the converter on my 2001. My cousin is one who likes to piece things together. I'll share your comment with him and hopefully he will listen to your advise.